  vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 page 1 of 6 set your site on vicor at www.vicorpower.com input voltage operating storage i = 40 to + 85 i = 55 to +100 m = 55 to + 85 m = 65 to +100 overtemperature shutdown 95? typical (recycle power to restart) features inputs: 28 vdc per mil-std-704d/e/f 155 vdc per mil-std-1399a 270 vdc per mil-std-704d/e/f ? single output: 2 ? 48 vdc ? up to 23 w/in 3 ? mil-std-810 environments ? up to 90% efficiency ? remote sense ? current limit ? ovp and thermal shutdown ? power boosters for higher power outputs ? zcs power architecture ? low noise fm control ? size: 4.6" x 2.4" x 0.5" (116,8 x 61,0 x 12,7 mm) product highlights the mi-200 family of dc-dc converters is designed for applications utilizing distributed power architectures. based on vicor?s vi-200 / vi-j00 family of zero-current switching, component level dc-dc converters, the mi-200 family offers exceptional performance in terms of power density, efficiency, noise, ease of use, and reliability. fully encapsulated in vicor?s industry standard package, the mi-series meets mil-std-810 environmental requirements for humidity, fungus, salt-fog, explosive atmosphere, acceleration, vibration, and shock. standard features such as wide output trimming/programming, current limiting, remote sense, output inhibit, and latching ovp and otp combine to offer the highest degree of protection, versatility, and reliability for power systems. packaging options standard: slotted baseplate slimmod: flangeless baseplate, option suffix: - s example: mi - 2xx - xx - s finmod: finned heat sink, option suffix: - f1, - f2, -f3 or -f4 examples: mi - 2xx - xx - f1 , 0.25" fins, longitudinal mi - 2xx - xx - f2 , 0.50" fins, longitudinal mi - 2xx - xx - f3 , 0.25" fins, transverse mi - 2xx - xx - f4 , 0.50" fins, transverse 5 v < 5 v y = 50 w y = 10 a x = 75 w x = 15 a w = 100 w w = 20 a v = v = 30 a for additional output power, 100 w and 75 w booster modules available change (mi- 2 xx-xx) to (mi- b xx-xx) z = 2.0 v y = 3.3 v 0 = 5.0 v x = 5.2 v w = 5.5 v v = 5.8 v t = 6.5 v [d] r = 7.5 v [d] m = 10 v 1 = 12 v p = 13.8 v 2 = 15 v n = 18.5 v 3 = 24 v l = 28 v j = 36 v k = 40 v 4 = 48 v mi-2 converter selection chart semi-custom driver and booster modules available, consult factory. product grade temperature ( c) output power/current v out output voltage nominal range transient [a] notes 2 = 28 v 18 50 v [b] 60 v 28 vdc input per mil-std 704d/e/f 5 = 155 v 100 210 v 230 v 155 vdc input per mil-std-1399a 6 = 270 v 125 400 v [c] 475 v 270 vdc input per mil-std-704d/e/f 7 = 165 v 100 310 v n/a data sheet mi-200 dc-dc converters 50 to 100 watts [d] 75 w max power for 28 v input [a] transient voltage for 1 second [b] 16 v operation at 75% load [c] these units rated at 75% load from 125 ?150 vin: mi-26z-xv, mi-26y-xv, mi-260-xw
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 page 2 of 6 set your site on vicor at www.vicorpower.com parameter min typ max units test conditions inrush charge 120 x 10 -6 200 x 10 -6 coulombs nominal line input reflected 10% i in nominal line, full load ripple current ?pp input ripple rejection db 120 hz, nominal line db 2400 hz, nominal line no load power dissipation 1.35 2 watts parameter min typ max units test conditions gate out impedance 50 ohms gate in impedance 1000 ohms gate in open circuit voltage 6 volts use open collector gate in low threshold 0.65 volts gate in low current 6 ma power sharing accuracy 0.95 1.05 parameter min typ max units test conditions setpoint accuracy 0.5% 1% v nom load/line regulation 0.05% 0.2% v nom ll to hl, 10% to full load 0.2% 0.5% v nom ll to hl, no load to 10% output temperature drift 0.01 0.02 % / ? over rated temperature long term drift 0.02 %/1k hours output ripple ?pp 100 150 mv whichever is greater 1.0% 1.5% v nom 20 mhz bandwidth trim range [a] 50% 110% v nom total remote 0.5 volts sense compensation ovp set point [b] 115% 125% 135% v nom latching current limit 105% 125% i nom automatic restart short circuit current [c] 20% 130% i nom converter specifications (typical at t bp = 25c, nominal line and 75% load, unless otherwise specified) 30 + 20 log ( v in ) v out 20 + 20 log ( v in ) v out input specifications output characteristics control pin specifications [a] 10 v, 12 v and 15 v outputs, standard trim range ?0%. consult factory for wider trim range. 3.3 v output trim range 2.20 to 3.63 v [b] no over temperature or voltage protection in booster modules [c] output voltages of 5 v or less incorporate foldback current limiting; outputs of 10 v and above provide constant current limitin g.
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 page 3 of 6 set your site on vicor at www.vicorpower.com parameter min typ max units test conditions efficiency 80 ?90% baseplate to sink 0.07 ?/watt with thermal pads thermal impedance thermal shutdown [ d] 90 95 105 ? cool and recycle power (drivers only) to restart converter specifications (cont.) parameter min typ max units test conditions input to output 3,000 v rms baseplate earthed output to baseplate 500 v rms input to baseplate 1,500 v rms input to output capacitance 50 75 pf parameter min typ max units test conditions altitude - method 500.2 70,000 feet procedure ii humidity - method 507.2 86 / 240 % / hours procedure i, cycle 1 acceleration - method 513.3 9 g procedure ii vibration - method 514.3 20 g procedure i, category 6 shock - method 516.3 40 g procedure i dielectric withstand characteristics thermal characteristics environmental ?mil-std-810d parameter min typ max units test conditions 25? ground benign: g.b. 3,552 1,000 hours 50? naval sheltered: n.s. 639 1,000 hours 65? airborne inhabited cargo: a.i.c. 501 1,000 hours reliability - mil-hdbk-217f (mi-22l-mw) parameter min typ max units test conditions weight 6.0 ounces (170) (grams) mechanical specifications [d] no over temperature or voltage protection in booster modules
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 page 4 of 6 set your site on vicor at www.vicorpower.com parameter i-grade m-grade storage temperature -55? to +100? -65? to +100? operating temperature (baseplate) -40? to +85? -55? to +85? power cycling burn-in 12 hours, 29 cycles 96 hours, 213 cycles temperature cycled with power off 12 cycles 12 cycles 17? per minute rate of change -65? to +100? -65? to +100? test data supplied at these temperatures [e] -40?, +80? -55?, +80? warranty 2 years 2 years environmental compliance mil-std-810 mil-std-810 derating navmat p-4855-1a navmat p-4855-1a product grade specifications converter specifications (cont.) [e] test data available for review or download from vicorpower.com parameter qualification altitude mil-std-810d, method 500.2, procedure iii, explosive decompression (40 k ft.). mil-std-810d, method 500.2, procedure ii, 40,000 ft., 1000 ?1500 ft./ min. to 70,000 ft., unit functioning explosive atmosphere mil-std-810c, method 511.1, procedure i vibration mil-std-810d, method 514.3, procedure i, category 6, helicopter, 20 g mil-std-810d, method 514.3 random: 10 ?300 hz @ 0.02 g 2 /hz, 2000 hz @ 0.002 g 2 / hz, 3.9 total g rms 3 hrs / axis. sine: 30 hz @ 20 g, 60 hz @ 10 g, 90 hz @ 6.6 g, 120 hz @ 5.0 g, 16.0 total g rms, 3 axes mil-std-810e, method 514.4, table 514.4-vii, ? db / octave, 7.7 g rms, 1hr / axis shock mil-std-810d, method 516.3, procedure i, functional shock, 40 g mil-std-202f, method 213b, 18 pulses, 60 g, 9 msec mil-std-202f, method 213b, 75 g, 11 ms saw tooth shock mil-std-202f, method 207a, 3 impacts / axis, 1, 3, 5 feet acceleration mil-std-810d, method 513.3, procedure ii operational test, 9 g for 1 minute along 3 mutually perpendicular axes humidity mil-std-810d, method 507.2, procedure i, cycle i, 240 hrs, 88% relative humidity solder test mil-std-202, method 208, 8 hr. aging fungus mil-std-810c, method 508.1 salt-fog mil-std-810c, method 509.1 environmental qualifications
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 page 5 of 6 set your site on vicor at www.vicorpower.com +.030 (0,76) -.000 (0) product id this surface full r 5 6 7 8 9 4 3 2 1 pin # 1 2 3 4 5 6* 7* 8* 9 function +in gate in gate out -in +out +sense trim -sense -out * do not connect on booster modules aluminum base .01 .040 (1,0) dia (7) places solder plate over copper alloy 0.080 (2,0) dia (2) places solder plate over copper alloy .30 .015 (7,6) (0,38) 1.80 (45,7) (106,7) (12,7) (5,6) min (3,0) (116,8) (61,0) (44,5) (7,6) min .15 (3,8) 2.10 (53,3) .40 (10,2) .35 .015 (8,9) (0,38) 1.40 (35,6) 1.00 (25,4) .70 (17,8) (91,4) .50 (12,7) vi-200 4.60 3.60 .15 (3,8) 4.20 .12 .22 .50 .30 2.40 1.75 standard 0.080 (2,0) dia (2) places matte tin over copper alloy rohs standard .040 (1,0) dia (7) places matte tin over copper alloy rohs mechanical drawing mi-200 note: for alternate packaging options refer to the mechanical drawing page of vicorpower.com
vicor corp. tel: 800-735-6200, 978-470-2900 fax: 978-475-6715 mi-200 dc-dc converters 50 to 100 watts rev. 1.2 3/07 set your site on vicor at www.vicorpower.com vicor corporation 25 frontage road andover, ma, usa 01810 tel: 800-735-6200 fax: 978-475-6715 email customer service: custserv@vicorpower.com technical support: apps@vicorpower.com vicor s comprehensive line of power solutions includes high density ac-dc and dc-dc modules and accessory components, fully configurable ac-dc and dc-dc power supplies, and complete custom power systems. information furnished by vicor is believed to be accurate and reliable. however, no responsibility is assumed by vicor for its use. vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunc- tion could result in injury or death. all sales are subject to vicor?s terms and conditions of sale, which are available upon request. specifications are subject to change without notice. intellectual property notice vicor and its subsidiaries own intellectual property (including issued u.s. and foreign patents and pending patent applications) relating to the products described in this data sheet. interested parties should contact vicor's intellectual property department. warranty vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. this warranty does not extend to products subjected to misuse, accident, or improper application or maintenanc e. vicor shall not be liable for collateral or consequential damage. this warranty is extended to the original purchaser only. except for the foregoing express warranty, vicor makes no warranty, express or implied, including, but not limited to, the warranty of merchantability or fitness for a particular purpose. vicor will repair or replace defective products in accordance with its own best judgement. for service under this warranty, the buyer must contact vicor to obtain a return material authorization (rma) number and shipping instructions. products returned without prior authorization will be returned to the buyer. the buyer will pay all charges incurred in returning the product to the factory. vicor will pay all reshipment charges if the product was defective within the terms of this warranty. information published by vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. vicor reserves the right to make changes to any products without further notice to improve reliability, funct ion, or design. vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it con- vey any license under its patent rights nor the rights of others. vicor general policy does not recommend the use of its compo- nents in life support applications wherein a failure or malfunction may directly threaten life or injury. per vicor terms and conditions of sale, the user of vicor components in life support applications assumes all risks of such use and indemnifies vic or against all damages.


▲Up To Search▲   

 
Price & Availability of MI-262-IX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X